Mantis Bug Tracker

View Issue Details Jump to Notes ] Issue History ] Print ]
IDProjectCategoryView StatusDate SubmittedLast Update
0004286Dwarf FortressDwarf Mode -- Jobs, Eating/Drinkingpublic2011-03-21 08:212014-01-21 18:14
ReporterGreenSpinach 
Assigned ToFootkerchief 
PrioritynormalSeverityminorReproducibilityalways
StatusresolvedResolutionduplicate 
PlatformOSOS Version
Product Version0.31.18 
Target VersionFixed in Version 
Summary0004286: Removing a well makes water undrinkable even if it was drinkable before the well was built
DescriptionA well is a valid water source only for Drink, not for Give Water or for Fill Pond. Also, removing a well makes that square no longer a valid water source for anything, even if, before the construction of the well, it was a valid water source for all purposes, and the only thing that's changed is the construction and removal of the well.
Steps To Reproduce1. Near an undrinkable pond, create a minimal water tank consisting of a constructed floor, 7 constructed walls, and the business end of a screw pump. Of course, the other end of the pump must be next to, and facing towards, the pond.
2. Build a ramp so that dwarves can walk on top of the wall.
3. Operate the pump to fill the tank.
4. Notice that you can place a valid Water Source zone over the water in the tank.
5. Build a well on top of the tank.
6. Deconstruct the well.
7. Notice that the top of the tank is no longer a valid water source.
TagsNo tags attached.
Attached Files

- Relationships
duplicate of 0001007new Wells become unusable after being used for anything other than drinking 

-  Notes
(0017046)
GreenSpinach (reporter)
2011-04-04 04:20

Actually it's a lot worse than that. Water source zones and wells that used to be valid become invalid for NO REASON AT ALL. This has happened to me at least 5 times, and each time, the only thing that's changed is I drew a few bucketfuls/drinks of water from the well or water source, then pumped more water into the cistern. The cistern always consists entirely of constructed walls and floors.

- Issue History
Date Modified Username Field Change
2011-03-21 08:21 GreenSpinach New Issue
2011-03-21 08:25 Logical2u Relationship added related to 0001007
2011-04-04 04:20 GreenSpinach Note Added: 0017046
2014-01-21 18:14 Footkerchief Relationship replaced duplicate of 0001007
2014-01-21 18:14 Footkerchief Status new => resolved
2014-01-21 18:14 Footkerchief Resolution open => duplicate
2014-01-21 18:14 Footkerchief Assigned To => Footkerchief


Copyright © 2000 - 2010 MantisBT Group